Search results for " Electrochemical Techniques"
showing 3 items of 3 documents
Height as a potential indicator of early life events predicting Parkinson's disease: a case-control study.
2007
Aim of this study was to investigate the relationship between height in young adult age and Parkinson's disease (PD) risk. We included 266 persons affected by idiopathic PD. Patients were matched by age and sex to 266 controls by a random selection from the municipality of residence. We collected information about height preceding PD from official documents where these characteristics referred to young adult age (nearly 30 years). We compared height in cases and controls by calculating differences in mean distribution and by χ2 analyses. Crude and adjusted odds ratios (OR) and 95% confidence intervals (CI) were calculated by logistic regression models. Mean height was significantly lower in…
Highly selective detection of Epinephrine at oxidized Single-Wall Carbon Nanohorns modified Screen Printed Electrodes (SPEs)
2014
Oxidized Single-Wall Carbon Nanohorns (o-SWCNHs) were used, for the first time, to assemble chemically modified Screen Printed Electrodes (SPEs) selective towards the electrochemical detection of Epinephrine (Ep), in the presence of Serotonine-5-HT (S-5HT), Dopamine (DA), Nor-Epineprhine (Nor-Ep), Ascorbic Acid (AA), Acetaminophen (Ac) and Uric Acid (UA). The Ep neurotransmitter was detected by using Differential Pulse Voltammetry (DPV), in a wide linear range of concentration (2-2500 μM) with high sensitivity (55.77 A M(-1) cm(-2)), very good reproducibility (RSD% ranging from 2 to 10 for different SPEs), short response time for each measurement (only 2s) and low detection of limit (LOD=0.…
Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat
2022
Wearable sensors for sweat biomarkers can provide facile analyte capability and monitoring for several diseases. In this work, a green wearable sensor for sweat absorption and chloride sensing is presented. In order to produce a sustainable device, polylactic acid (PLA) was used for both the substrate and the sweat absorption pad fabrication. The sensor material for chloride detection consisted of silver-based reference, working, and counter electrodes obtained from upcycled compact discs. The PLA substrates were prepared by thermal bonding of PLA sheets obtained via a flat die extruder, prototyped in single functional layers via CO2 laser cutting, and bonded via hot-press. The effect of co…